Picture may vary.

RAILNEX Cable Connector, Size 2, for Railway Application, up to 25 kV

RAILNEX connects the rail vehicle’s traction transformer via a connection cable. The plug-in system, based on the proven PFISTERER CONNEX connector, was specifically designed for rail applications and enables a reliable connection in compliance with the fire safety standard EN 45545.

Application:

  • The pluggable cable connector is inserted into a RAILNEX socket installed in the traction transformer.
  • Connects the traction transformer to the 25 kV connection cable

Characteristics:

  • The separable connector is installed without any oilwork
  • Considerably reduced installation time and safe installation due to plug-in-technology
  • Horizontal, vertical and angeled connection possible
  • Rapid separation and change of cable and equipment possible
  • Touchproof and maintenance-free
  • No leakage and environmental risks due to dry-type insulation
  • Flame-resistant according to EN 45545-2
  • Variant creation based on cable data is possible

Technical Data

Article no. 821 999 001
Size 2
Max. system voltage UNm (kV) 27.5
Nominal voltage Un (kV) 25
Network single-phase
Applicable standards EN 50180-1, IEC 60850, DIN EN 50467, DIN EN 60137, DIN EN 50124-1, DIN EN 60077-1, DIN EN 50163
Working place indoor and outdoor
Lightning impulse withstand voltage BIL (kV) 200
AC withstand voltage - 5 min (kV) 95
Partial discharge test < 10pC at (kV) 42
Rated current In (A) 800
Rated short-time withstand current 3 s Ith (kA) 25
Max. dynamic short circuit current Id (kA) 125
Cable specification (N)TMCWOEU
Conductor material copper
Conductor diameter stranded circular (mm) 12.0 - 13.5
Conductor cross section stranded circular (mm2) 95, class 5 (RF)
Diameter over insulation (mm) 28.0 - 31.5
Shock and vibration test - DIN EN 61373 category 1 class B
Flame-resistant EN 45545-2
Protection type - DIN EN 60529 IP 67