HVC8 Connector, Variant 113, with Cable, Assembled
3-pole, straight connector with one screw as locking mechanism.
Adapted to high voltage cable Radox Elastomere 35 mm2 from company Huber & Suhner.
Compatible receptacle: 382 005 102 or upgrade kit
(B- to C-sample) 389 015 401.
Product validation according to specification ZF AVE 130.
Technical Data
Article no. | 382 999 999 00053 | |
---|---|---|
Type designation | CC-HVC8-35_RadoxS-3-180°-A-CR-SF-SC-NI-113 | |
Cable length | (m) | 14 |
HVC8 Electric contact | Ø (mm) | 8 |
Number of power contacts | 3 | |
Connection type | 35 mm2 compressed | |
Housing | Aluminium (sea water resistant), straight | |
Mechanical Coding | A | |
Service life | 60.000 / 12 | |
Contact surface | silver plated copper | |
Locking mechanism | one central screw | |
Mating cycles | 50 | |
Cable cross section | (mm2) | 35 |
Suitable high voltage cable | 100 103 509 | |
Suitable high voltage cable | 84100296 | |
Rated voltage | (V) | 900, DIN EN 60664-1, 4000m NN |
Electrical withstand voltage | (kV DC) | 2.7 |
IP protection class DIN 40050-9 | IP 6K9K, IP X7, IP X6K | |
IP protection class DIN 40050-9 not mounted | IP 20 | |
Screening effectiveness | (dB) | >55 dB for f = 0,1 MHz up to 100 MHz |
Corrosion resistance | 672 hours, ISO 16750-4, Chapter 5.5.2 | |
Nominal current | (A) | 220 (Contact) |
Overload current capability | (A/0,1s @ 80° C) | 4000 |
Overload current capability | (A/1s @ 80° C) | 1400 |
Overload current capability | (A/5s @ 80° C) | 600 |
Overload current capability | (A/10s @ 80° C) | 450 |
High short circuit strength | (kA/0,1s @ 20° C) | 5 |
Rated shield current | (A) | 10 |
Max. shield current | (A) | 50 |
Ambient temperature | (°C) | -30 up to +85 |
Lower storage temperature | (°C) | -40 (48h) |
Upper storage temperature | (°C) | 100 (96h) |
Insertion force | (N) | < 100 |
Pull-off force | (N) | < 100 |
Side load on connector housing | (Nm) | 4 |
Downloads
Data sheet as pdf-fileDrawing as pdf-file
Accessories
© 2024 PFISTERER Holding SE
We reserve the right to make technical changes.
We reserve the right to make technical changes.
the power connection