Test Accessories
Size 0
Size 1
Size 2
Size 3
conductor clamps
Applicable standards …
EN 50181
EN 50180
DIN VDE 0278-629
Size …
0
1
2
3
3-S
Max. system voltage …
24.0
36.0
42.0
52.0
Test Accessories
Article no.
Designation
827 186 210
CONNEX Test and Transition Connector, Size 0, U
m
= 24 kV, I
n
= 250 A, U(AC - 5 min) = 54 kV, U(LI) = 125 kV, turnable
827 186 211
CONNEX Test and Transition Connector, Size 1, U
m
= 36 kV, I
n
= 630 A, U(AC - 5 min) = 81 kV, U(LI) = 170 kV, turnable
827 186 212
CONNEX Test and Transition Connector, Size 2, U
m
= 42 kV, I
n
= 800 A, U(AC - 5 min) = 95 kV, U(LI) = 200 kV, turnable
827 186 214
CONNEX Test and Transition Connector, Size 2, U
m
= 42 kV, I
n
= 800 A, U(AC - 5 min) = 95 kV, U(LI) = 200 kV, not turnable
827 186 213
CONNEX Test and Transition Connector, Size 3, U
m
= 42 kV, I
n
= 800 A, U(AC - 5 min) = 95 kV, U(LI) = 200 kV, turnable
827 181 010
CONNEX Grounding and Current Testing Connector, Size 0, I
n
= 250 A, U
max
= 2 kV, outdoor-resistant
827 181 011
CONNEX Grounding and Current Testing Connector, Size 1, I
n
= 630 A, U
max
= 2 kV, outdoor-resistant
827 181 012
CONNEX Grounding and Current Testing Connector, Size 2, I
n
= 800 A, U
max
= 2 kV, outdoor-resistant
827 181 013
CONNEX Grounding and Current Testing Connector, Size 3, I
n
= 1250 A, U
max
= 2 kV, outdoor-resistant
810 105 110
Test lead size 1, 36 kV, 95 mm
2
810 105 113
Test lead size 1, 36 kV, 95 mm
2
810 105 210
Test lead size 2, 42 kV, 95mm
2
810 105 212
Test lead size 2, 42 kV, 95 mm
2
810 105 213
Test lead size 2, 42 kV, 95 mm
2
810 105 222
Test lead size 2, 42 kV, 95 mm
2
810 105 310
Test lead size 3, 42 kV, 95 mm
2
810 105 319
Test lead size 3, 42 kV, 95 mm
2
810 105 323
Test lead size 3, 42 kV, 95 mm
2
810 105 329
Test lead size 3, 42 kV, 95 mm
2
810 105 352
Test lead size 3-S, 52 kV, 95 mm
2
810 105 391
Test lead size 3-S, 52 kV, 400 mm
2
827 125 001
Cable Testing Socket, Size 1, not Scoop-Proof
827 125 002
Cable Testing Socket, Size 2, not Scoop-Proof
827 125 003
Cable Testing Socket, Size 3, not Scoop-Proof
827 130 001
CONNEX Blind Cap, Size 0, U
m
= 24 kV, scoop-proof
827 131 001
CONNEX Blind Cap, Size 1, U
m
= 36 kV, scoop-proof
827 132 001
CONNEX Blind Cap, Size 2, U
m
= 36 kV, scoop-proof
827 133 001
CONNEX Blind Cap, Size 3, U
m
= 52 kV, scoop-proof
Your request